{"product_id":"v-flow-pump-nv12-6s","title":"V-Flow Pump NV12-6S","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\n\u003cp\u003eThe V-Flow Pump NV12-6S is a high-efficiency, ten-stage vertical booster pump designed for industrial, commercial, and agricultural applications. Its vertical, in-line design saves valuable floor space while delivering reliable, consistent performance in demanding environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMotor Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSingle-Phase Motor\u003c\/strong\u003e\n        \u003cul\u003e\n            \u003cli\u003eIdeal for locations without three-phase power\u003c\/li\u003e\n            \u003cli\u003eProvides the same flow capacity and pressure as the three-phase model\u003c\/li\u003e\n            \u003cli\u003eSlightly lower electrical efficiency and better suited for lighter duty cycles\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis pump is well-suited for reverse osmosis, water treatment, irrigation, sprinkler systems, hot and cold water circulation, and general water boosting applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe V-Flow Pump NV12-6S combines precision engineering with dependable performance, making it a trusted choice for a wide range of water handling needs.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* STYLING FOR SPEC TABLES *\/\n.spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    text-align: center;\n    margin-bottom: 1em;\n}\n\n.spec-table th {\n    background-color: rgb(23, 23, 150);\n    color: white;\n    padding: 1em;\n}\n\n.spec-table tr:nth-child(even) {\n    background-color: #ebebeb;\n}\n\n.table-header-link {\n    text-decoration: none;\n    color: white;\n}\n\n.spec-table td {\n    padding: 1em;\n}\n\n.spec-table td:first-child {\n        font-weight: 700;\n}\n\u003c\/style\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003ch2\u003eV-Flow Pump NV12-6S\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Multistage Booster Pump – 304 Stainless Steel\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003c!-- Technical Specs --\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n    \u003ctr\u003e\n        \u003cth colspan=\"2\"\u003eTechnical Specifications\u003c\/th\u003e\n    \u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n    \u003ctd\u003eRated Flow\u003c\/td\u003e\n    \u003ctd\u003e12 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eStages\u003c\/td\u003e\n    \u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMax Working Pressure\u003c\/td\u003e\n    \u003ctd\u003e362 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMax Inlet Pressure\u003c\/td\u003e\n    \u003ctd\u003e150 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMotor Power\u003c\/td\u003e\n    \u003ctd\u003e1 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMotor Phase \/ Frequency\u003c\/td\u003e\n    \u003ctd\u003e1PH \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMotor Frame\u003c\/td\u003e\n    \u003ctd\u003e56C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMotor Enclosure\u003c\/td\u003e\n    \u003ctd\u003eT - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003ePump Length (Flanged)\u003c\/td\u003e\n    \u003ctd\u003e14.13 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eWeight (Flanged)\u003c\/td\u003e\n    \u003ctd\u003e36 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\n\u003c!-- PARTS AND COMPONENTS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003ch3\u003eConstruction \u0026amp; Design Features (304 Stainless Steel Model)\u003c\/h3\u003e\n\n\u003c!-- MATERIALS FOR NV6 - NV85B --\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth\u003eComponent\u003c\/th\u003e\n  \u003cth\u003eMaterial (304 SS Models)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd\u003eMotor Bracket\u003c\/td\u003e\n  \u003ctd\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003ePump Head\u003c\/td\u003e\n  \u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eImpeller\u003c\/td\u003e\n  \u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eDiffuser\u003c\/td\u003e\n  \u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eNeck Ring\u003c\/td\u003e\n  \u003ctd\u003eTeflon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eShaft\u003c\/td\u003e\n  \u003ctd\u003e431 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eCasing\u003c\/td\u003e\n  \u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eO-Ring\u003c\/td\u003e\n  \u003ctd\u003eEPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003ePump Base\u003c\/td\u003e\n  \u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eBase Plate\u003c\/td\u003e\n  \u003ctd\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eMechanical Seal\u003c\/td\u003e\n  \u003ctd\u003eSilicon Carbide\/Silicon Carbide\/EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- INSTALLATION INSTRUCTIONS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1286\/9985\/files\/NV12-6SWeb.pdf?v=1755530901\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"installation-instructions\"\u003e\n\u003ch2\u003eInstallation Instructions for V-Flow Pump NV12-6S\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreparation:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the pump and motor for any damage during shipment. Report any damage immediately to the carrier or dealer.\u003c\/li\u003e\n\u003cli\u003eEnsure the installation site is level, stable, and provides sufficient space and ventilation for service and motor cooling.\u003c\/li\u003e\n\u003cli\u003eCheck that the pump model matches the job requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting the Pump:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the pump base to a solid, flat surface to prevent vibrations during operation.\u003c\/li\u003e\n\u003cli\u003eAlign and support suction and discharge piping to avoid undue strain on the pump.\u003c\/li\u003e\n\u003cli\u003eInstall isolation valves on both the suction and discharge sides for maintenance convenience.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping Connections:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure piping is properly sized and matches the pump's flanged connections (1.25” ANSI 150#).\u003c\/li\u003e\n\u003cli\u003eInstall gaskets on flanges to prevent leaks. Ensure they do not restrict flow.\u003c\/li\u003e\n\u003cli\u003eRemove any protective stickers or caps from the suction and discharge flanges.\u003c\/li\u003e\n\u003cli\u003eFor hot water systems, include a bleed valve in the discharge line to relieve pressure during service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHave a certified electrician verify the electrical supply matches the pump motor's specifications (1-phase, TEFC).\u003c\/li\u003e\n\u003cli\u003eCheck motor wiring for correct rotation. Rotation should be counterclockwise when viewed from the motor's rear.\u003c\/li\u003e\n\u003cli\u003eFor 3-phase motors, reverse any two leads to correct rotation if needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePriming the Pump:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the fill plug and fill the pump casing with water using a funnel.\u003c\/li\u003e\n\u003cli\u003eOpen the vent plug's 9mm needle valve to allow air to escape while filling.\u003c\/li\u003e\n\u003cli\u003eClose the valve and reinstall the fill plug once water flows steadily from the vent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOpen the suction valve fully and partially open the discharge valve.\u003c\/li\u003e\n\u003cli\u003eApply power to the motor and check for smooth operation without noise or vibration.\u003c\/li\u003e\n\u003cli\u003eGradually open the discharge valve to desired operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Precautions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNever operate the pump without water. This can damage internal components.\u003c\/li\u003e\n\u003cli\u003eAlways replace coupling guards after installation to prevent injuries.\u003c\/li\u003e\n\u003cli\u003eEnsure the pump is properly grounded and free from leaks before starting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Crystal Quest Water Filters","offers":[{"title":"Default Title","offer_id":52627093389493,"sku":"SWP-NV12B6FE1T","price":4349.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1015\/2879\/7365\/files\/nv12b6fe1t-vertical-pump-crystal-quest-water-filters-36773524340829.jpg?v=1780773006","url":"https:\/\/frankysplug.myshopify.com\/products\/v-flow-pump-nv12-6s","provider":"Franky’sPlug","version":"1.0","type":"link"}