{"product_id":"v-flow-pump-nv65-4s","title":"V-Flow Pump NV65-4S","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSWP V-Flow Pump NV65-4S\u003c\/strong\u003e is a high-performance, multi-stage booster pump designed to handle demanding industrial, commercial, and agricultural applications. Its compact, vertical in-line design saves space while delivering exceptional reliability and efficiency.\u003c\/p\u003e\n\u003cp\u003eEquipped with a robust 7.5 HP single-phase motor, the \u003cstrong\u003eV-Flow Pump NV65-4S\u003c\/strong\u003e offers a flow rate of up to 65 GPM and can handle pressures up to 232 PSI. Constructed from premium 304 stainless steel, it provides excellent durability and corrosion resistance, ensuring long-lasting performance in various environments. Maintenance-free cartridge mechanical seals and ANSI standard flanged connections simplify installation and servicing.\u003c\/p\u003e\n\u003cp\u003eCertified to meet NSF\/ANSI 61 and 372 standards, this pump is ideal for applications such as reverse osmosis, water boosting, filtration systems, heat exchangers, and hot and cold water circulation. Combining high-quality materials, precision engineering, and versatile functionality, the V-Flow Pump NV65-4S is an outstanding choice for efficient water handling solutions.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* STYLING FOR SPEC TABLES *\/\n.spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    text-align: center;\n    margin-bottom: 1em;\n}\n\n.spec-table th {\n    background-color: rgb(23, 23, 150);\n    color: white;\n    padding: 1em;\n}\n\n.spec-table tr:nth-child(even) {\n    background-color: #ebebeb;\n}\n\n.table-header-link {\n    text-decoration: none;\n    color: white;\n}\n\n.spec-table td {\n    padding: 1em;\n}\n\n.spec-table td:first-child {\n        font-weight: 700;\n}\n\u003c\/style\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003ch2\u003eV-Flow Pump NV65-4S\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Multistage Booster Pump – 304 Stainless Steel\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003c!-- Technical Specs --\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n    \u003ctr\u003e\n        \u003cth colspan=\"2\"\u003eTechnical Specifications\u003c\/th\u003e\n    \u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n    \u003ctd\u003eRated Flow\u003c\/td\u003e\n    \u003ctd\u003e65 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eStages\u003c\/td\u003e\n    \u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMax Working Pressure\u003c\/td\u003e\n    \u003ctd\u003e232 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMax Inlet Pressure\u003c\/td\u003e\n    \u003ctd\u003e118 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMotor Power\u003c\/td\u003e\n    \u003ctd\u003e7.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMotor Phase \/ Frequency\u003c\/td\u003e\n    \u003ctd\u003e1PH \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMotor Frame\u003c\/td\u003e\n    \u003ctd\u003e213TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eMotor Enclosure\u003c\/td\u003e\n    \u003ctd\u003eT - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003ePump Length (Flanged)\u003c\/td\u003e\n    \u003ctd\u003e21.22 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n    \u003ctd\u003eWeight (Flanged)\u003c\/td\u003e\n    \u003ctd\u003e94 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\n\u003c!-- PARTS AND COMPONENTS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003ch3\u003eConstruction \u0026amp; Design Features (304 Stainless Steel Model)\u003c\/h3\u003e\n\n\u003c!-- MATERIALS FOR NV6 - NV85B --\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth\u003eComponent\u003c\/th\u003e\n  \u003cth\u003eMaterial (304 SS Models)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd\u003eMotor Bracket\u003c\/td\u003e\n  \u003ctd\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003ePump Head\u003c\/td\u003e\n  \u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eImpeller\u003c\/td\u003e\n  \u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eDiffuser\u003c\/td\u003e\n  \u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eNeck Ring\u003c\/td\u003e\n  \u003ctd\u003eTeflon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eShaft\u003c\/td\u003e\n  \u003ctd\u003e431 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eCasing\u003c\/td\u003e\n  \u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eO-Ring\u003c\/td\u003e\n  \u003ctd\u003eEPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003ePump Base\u003c\/td\u003e\n  \u003ctd\u003e304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eBase Plate\u003c\/td\u003e\n  \u003ctd\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eMechanical Seal\u003c\/td\u003e\n  \u003ctd\u003eSilicon Carbide\/Silicon Carbide\/EPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- INSTALLATION INSTRUCTIONS --\u003e\n\u003cp\u003e###\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1286\/9985\/files\/NV65-4SWeb.pdf?v=1755530901\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"installation-instructions\"\u003e\n\u003ch2\u003eInstallation Instructions for V-Flow Pump NV65-4S Vertical Pump\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreparation:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the pump and motor for any visible damage during shipping. Report any damage to the carrier or dealer immediately.\u003c\/li\u003e\n\u003cli\u003eEnsure the installation site is level, stable, and provides adequate space and ventilation for motor cooling and servicing.\u003c\/li\u003e\n\u003cli\u003eVerify that the pump model matches the system requirements and intended application.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting the Pump:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the pump base to a solid, flat surface to minimize vibrations during operation.\u003c\/li\u003e\n\u003cli\u003eAlign and support the suction and discharge piping to prevent undue strain on the pump.\u003c\/li\u003e\n\u003cli\u003eInstall isolation valves on both the suction and discharge sides for easy maintenance and servicing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping Connections:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure piping matches the pump’s 2\" ANSI 150# flanged connections.\u003c\/li\u003e\n\u003cli\u003eInstall appropriate gaskets to prevent leaks and ensure unobstructed flow.\u003c\/li\u003e\n\u003cli\u003eRemove any protective covers or caps from the flanges before installation.\u003c\/li\u003e\n\u003cli\u003eFor hot water systems, include a bleed valve in the discharge line to relieve pressure during maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHave a certified electrician verify that the electrical supply matches the motor’s specifications (5 HP, single-phase).\u003c\/li\u003e\n\u003cli\u003eEnsure proper motor wiring and confirm counterclockwise rotation when viewed from the motor’s rear.\u003c\/li\u003e\n\u003cli\u003eIf rotation is incorrect, consult the motor’s wiring instructions for correction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePriming the Pump:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRemove the fill plug and use a funnel to fill the pump casing with water.\u003c\/li\u003e\n\u003cli\u003eOpen the vent plug to allow air to escape as the pump fills with water.\u003c\/li\u003e\n\u003cli\u003eRe-seal the vent plug and fill plug once a steady stream of water flows from the vent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial Testing:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOpen the suction valve fully and partially open the discharge valve.\u003c\/li\u003e\n\u003cli\u003eApply power to the motor and check for smooth operation without noise or vibration.\u003c\/li\u003e\n\u003cli\u003eGradually open the discharge valve to achieve desired operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Precautions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNever operate the pump without water to avoid damage to internal components.\u003c\/li\u003e\n\u003cli\u003eReplace coupling guards after installation to ensure operator safety.\u003c\/li\u003e\n\u003cli\u003eEnsure the pump is properly grounded and all connections are secure before starting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Crystal Quest Water Filters","offers":[{"title":"Default Title","offer_id":52628767015093,"sku":"SWP-NV65B4FE1T","price":8074.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1015\/2879\/7365\/files\/nv45b5fe3t-booster-pump-45gpm-crystal-quest-water-filters-36839740473437.jpg?v=1780774628","url":"https:\/\/frankysplug.myshopify.com\/products\/v-flow-pump-nv65-4s","provider":"Franky’sPlug","version":"1.0","type":"link"}